Leave Your Message
Replace with lead-acid batter power module

Replacement lead acid

Replacement lead acid (2)
01

technical specifications

Model

12V 100Ah

Nominal Voltage

12V 

Rated Capacity

100Ah 

Internal Impedance 

≤20mΩ  

Standard Charge Cut-off Voltage

14.6V  

Standard Discharge Cut-off Voltage

10V  

Maximum Continuous charge Current

50A (0.5C)  

Maximum Continuous Discharge Current

100A (1C)

Maximum Pulse       charge/Discharge Current  (10s)

200A (2C) 

Operating Temperature Range

‘-20℃~60 ℃

Storage Temperature Range

-20℃~45℃ 

Dimension

260*168*209mm 

Weight

 13 kg 

Cycle life

≥6000

12V 200Ah
01

technical specifications

Model

12V 200Ah

Nominal Voltage

12V 

Rated Capacity

200Ah

Internal Impedance 

≤15mΩ  

Standard Charge Cut-off Voltage

14.6V  

Standard Discharge Cut-off Voltage

10V  

Maximum Continuous
charge Current

100A (0.5C)  

Maximum Continuous Discharge Current

200A (1C)

Maximum Pulse charge/Discharge Current  (10s)

400A (2C) 

Operating Temperature Range

‘-20℃~60 ℃

Storage Temperature Range

’-20℃~45℃ 

Dimension

406*173*236 mm

Weight

25kg

Cycle life

≥6000

12V 280Ah (2)
01

technical specifications

Model

12V 280Ah

Nominal Voltage

12V

Rated Capacity

280Ah

Internal Impedance 

≤12mΩ  

Standard Charge Cut-off Voltage

14.6V  

Standard Discharge Cut-off Voltage

10V  

Maximum Continuous
charge Current

140A (0.5C)  

Maximum Continuous Discharge Current

280A (1C)

Maximum Pulse charge/Discharge Current  (10s)

560A (2C) 

Operating Temperature Range

‘-20℃~60 ℃

Storage Temperature Range

‘-20℃~45℃ 

Dimension

530*240*220mm

Weight

35kg

Cycle life

≥6000

Replacement lead acid
01

technical specifications

Model

24V 200Ah 

Nominal Voltage

12V

Rated Capacity

200Ah

Internal Impedance 

 ≤25mΩ  

Standard Charge Cut-off Voltage

 29.2V  

Standard Discharge Cut-off Voltage

20V  

Maximum Continuous
charge Current

100A (0.5C)  

Maximum Continuous Discharge Current

200A (1C)

Maximum Pulse charge/Discharge Current  (10s)

400A (2C) 

Operating Temperature Range

‘-20℃~60 ℃

Storage Temperature Range

-20℃~45℃ 

Dimension

520*520*220mm

Weight

 About 50kg

Cycle life

≥6000

Replacement lead acid (1)
01

technical specifications

Model

48V 100Ah 

Nominal Voltage

12V

Rated Capacity

100Ah

Internal Impedance 

≤30mΩ  

Standard Charge Cut-off Voltage

 58.4V  

Standard Discharge Cut-off Voltage

 40V 

Maximum Continuous
charge Current

 50A (0.5C)  

Maximum Continuous Discharge Current

100A (1C)

Maximum Pulse charge/Discharge Current  (10s)

200A (2C)  

Operating Temperature Range

‘-20℃~60 ℃

Storage Temperature Range

-20℃~45℃ 

Dimension

600*500*220mm

Weight

55kg  

Cycle life

≥6000

feature

1. High energy density, small size, and light weight
-Volume comparison: Lithium batteries have a significantly smaller volume than lead-acid batteries of the same capacity. Traditional lead-acid batteries have a larger capacity and volume.

2. Long cycle life
-The cycle life of lithium batteries is ≥ 6000 times (under standard charge and discharge conditions), much higher than the 300-500 times of lead-acid batteries, and the long-term use cost is lower.

3. High charging and discharging efficiency
-Charging current: Supports 0.5C fast charging (such as 12V 100Ah supporting 50A charging), with faster charging speed.
-Discharge capability: Continuous discharge current up to 1C (such as 12V 100Ah supporting 100A discharge), pulse discharge up to 2C (10 seconds), meeting high-power requirements.

4. Wide working temperature range
-Working temperature: -20 ℃~60 ℃, suitable for severe cold and high temperature environments, with better performance than lead-acid batteries (poor low-temperature performance).

5. Strong voltage stability
-Discharge cut-off voltage: The 12V system can still operate after discharging to 10V, with a more stable voltage platform to avoid the problem of "voltage drop" in lead-acid batteries.

6. Low maintenance costs
-No need for regular water addition or balanced charging, low internal resistance (≤ 20m Ω @ 12V 100Ah), low self discharge rate, and better long-term storage performance.

7. Environmental friendliness
-Lithium batteries do not contain harmful substances such as lead and acid, which is more in line with environmental requirements.

8. Modular design is flexible
-Supports multiple voltage platforms (12V/24V/48V), easy to connect in series, suitable for different application scenarios (such as energy storage, two wheeled tricycles, etc.)

Application

Electric ship power compartment, communication base station backup power supply, new energy vehicles and AGV robot power units, etc.
Power Modules
Power Modules-2
Power Modules-3
Power Modules-34

FAQ

Q1. Can I have a sample order for this product?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

Q2. What about the lead time?
A:Sample needs 3-5 days, mass production time needs 1-2 weeks for order quantity more than

Q3. Do you have any MOQ limit for sample order?
A: Low MOQ, 1pc for sample checking is available

Q4. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.

Q5. How to proceed an order for the product?
A: Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.

Q6: Do you offer guarantee for the products?
A: Yes, we offer 1-2 years warranty to our formal products

By Zhongke TO KNOW MORE ABOUT Zhongke, PLEASE CONTACT US!

  • angela@zktpower.com
  • No. 8, Zhongjie South Road, Shuijing Town, Yantou Town, Pujiang County, Jinhua City, Zhejiang Province

Our experts will solve them in no time.